Stair calculator
Enter the floor-to-floor rise, the tallest riser you will accept, the tread depth and the stair width to get the number of risers, the equal riser height, the treads and the stringers.
Material list
36 in total rise, 7.75 in maximum riser, 10 in treads, 3 ft wide
- 4 stringers, cut from 8 ft boards
- 4 treads, 3 ft wide
| Measure | Yours | Typical | |
|---|---|---|---|
| Riser height | 7.2 in | at most 7.75 in | within |
| Tread depth | 10 in | at least 10 in | within |
| 2 × riser + tread | 24.4 in | 24–25 in | within |
| Stair width | 36 in | at least 36 in | within |
Typical ranges from the International Residential Code (IRC) and the 2R + T comfort rule. Not legal advice: your local code decides.
- Risers
- 5 at 7.2 in
- Treads
- 4
- Total run
- 40 in
- Stringer length (straight line)
- 4.48 ft
- Stringer board, at least
- 5.51 ft (adds one step for the cuts)
- Stringers
- 4
- Pitch
- 35.8°
Estimate only. For footings, steps, decks and stairs, follow your plans and local building code, and get a permit where one is required.
How it works
Measure the total rise from finished floor to finished floor. Enter the maximum riser height you want (7.75 inches by default), the tread depth (10 inches) and the stair width (3 ft).
The riser count is the total rise divided by the maximum riser, rounded up, so every riser is at or under your maximum. Each riser is then total rise divided by risers, which gives equal heights. The tread count is one fewer than the risers, because the upper floor is the last step.
Stringers are spaced across the width (16 inches apart by default) with at least two. The stringer length shown is the straight-line distance along the stringer; the board length it picks adds one step (the diagonal of one riser and one tread) for the top and bottom cuts, then takes the first stock length that fits. Unlike the other calculators, no waste percentage is added, and the counts are exact whole numbers.
The results are checked against typical ranges for riser height, tread depth, the 2R + T comfort rule and stair width (36 inches minimum in imperial). In metric the ranges are those for private stairs in England: rise 150 to 220 mm, going 220 to 300 mm, 2R + G 550 to 700 mm and a pitch of at most 42 degrees; width is not checked. These are shown as typical ranges only, not as code compliance.
The formula
- Risers = total rise ÷ maximum riser height, rounded up
- Riser height = total rise ÷ risers; treads = risers − 1
- Total run = treads × tread depth
- Stringer length = √(total rise² + total run²); the board to buy adds one step's diagonal, √(riser² + tread²), for the top and bottom cuts
- Stringers = stair width ÷ maximum spacing, rounded up, + 1 (at least 2)
Worked examples
36 in total rise, 7.75 in maximum riser, 10 in treads, 3 ft wide: 5 risers of 7.2 in, 4 treads, total run 40 in, stringer about 4.48 ft. Buy:
- 4 stringers, cut from 8 ft boards
- 4 treads, 3 ft wide
108 in total rise, 7.75 in maximum riser, 10.5 in treads, 4 ft wide: 14 risers of 7.714 in, 13 treads, total run 136.5 in, stringer about 14.5 ft. Buy:
- 4 stringers, cut from 16 ft boards
- 13 treads, 4 ft wide
2,600 mm total rise, 200 mm maximum riser, 240 mm treads, 1 m wide: 13 risers of 200 mm, 12 treads, total run 2,880 mm, stringer about 3.88 m. Buy:
- 4 stringers, cut from 4.2 m boards
- 12 treads, 1 m wide
Tips
- Measure total rise from finished floor to finished floor, including the flooring.
- Nudge the maximum riser up or down to land on a riser height you can cut cleanly.
- Check your local building code before you cut stringers; the checks here are typical ranges, not compliance.
Questions
How many stairs do I need for a 36 inch rise?
With the default 7.75 inch maximum riser: 5 risers at 7.2 inches each and 4 treads at 10 inches, a 40 inch run. The comfort figure (2R + T) is 24.4, inside the typical 24 to 25 range, and a 3 ft wide stair needs 4 stringers from 8 ft stock.
What is the 2R + T rule?
Twice the riser height plus the tread depth. The traditional rule of thumb puts the result between 24 and 25 inches for a comfortable flight (550 to 700 mm in metric). The calculator shows it as a typical range only.
Why is the tread count one less than the riser count?
The upper floor is the last step up, so a stair with 5 risers has 4 treads.
What is the maximum riser height?
The default is 7.75 inches (190 mm), and the calculator keeps every riser at or below the value you enter. The typical-range check uses a 7.75 inch maximum in imperial and 150 to 220 mm in metric. Your local building code sets the actual limit.
Does the calculator check building code compliance?
No. It compares riser, tread, comfort and width against typical ranges and shows them as guidance only. Confirm the limits in your local building code or with a qualified professional.
The full method, every constant and its source are published with the calculator code. Found a result that looks wrong? Email yardlist@lobbykit.net with the share link.